GTC Push Lock S2 2A 5P Field Installable Cable End Male Crimp

GT261211-1305X
Specifications:
Current Rating: 4.0A

AWG Gauge: 20 AWG ~ 24 AWG
Voltage: 5 PIN: 60V AC/DC
Temperature Range: -25° / +85°
Ingress Protection Rate : IP 68

    Our dedicated team of engineers will help you find the perfect cable solution.

Description

Download Drawing

Material
Housing/Base/CagePA66
Body/Hex Nut/Push Nut/Holder/Cover/Gland NutCopper Alloy
Metal Ball / SpringSUS
ContactsCopper Alloy With Au Plating
O-Ring/Gasket/GlandSilicone
GlueEpoxy
Technical Data
CharacteristicsDescription
Visual and Dimensional InspectionMust meet or exceed the requirements specified by the most current version of the GT2611 Specification.
Insulation ResistanceDC500V±10%‚ test for 1 minute and the insulation resistance should be more than 100MΩ
Withstanding Voltage650 VAC between contacts , 650 VAC between contacts and metal-housing, for 1±5s min.
Contact Resistance10mΩ at 10mA Max.
Pin Pull Test1. Initial: 24 N minimum.
2. After Test: 16 N minimum.
Durability2000 cycles insertion/extraction cycles at a maximum rate of 200cycles per hour.
Physical ShockNo discontinuities of 1 μs or longer duration when mated are subjected to 11 ms duration 30 Gs half-sine shock pulses. Three shocks in each direction applied along three mutually perpendicular planes for a total of 18 shocks.
Random VibrationThe electrical load conditions shall be 100mA maximum for all contacts.
Frequency: 50 to 2000 Hz
PDS: 0.04 g? /Hz.
Duration: 1 Hour/Axis, 3 Axes Total.
g’s: 7.56 g rms
Thermal Shock5 cycles at -40° / +105°, after the test, the function and appearance can’t be impacted.
Humidity Life96 hours minimum (seven step cycles).
Salt SprayThe test liquid (Nacl) thickness is 5%, Compressing the air pressure is 0.083Mpa, Spraying amount is 1~2 ml/80cm/h, Temperature of the pressure barrel is 43°, LAB temperature is 35°, relative humidity of LAB is 95%~98%, test time is 48hours, after the test, check if there is rusty and oxidized phenomenon.
Waterproof TestSubmersion in water 1 meter for 24 hours.
Temperature Life85° for 48Hours Method A, Mated
Cycling Humidity4 cycles at 25° / +85° 95%RH (1 cycles/day)
UV Exposure24Hr equal 1 year: Total require 3 years
8h UV at 70 (±3) ° Black Panel Temperature
4h Condensation at 50 (±3) ° Black Panel Temperature