GTC Power M35 41A Push Lock Panel Mount Female

GT1E1400-42030
Specifications:
Current Rating: 41A
Temperature Range: -40° / +105°
IP Rating: IP 67

    Our dedicated team of engineers will help you find the perfect cable solution.

Description

Download Drawing

UL

Material
HousingPA66
ContactsCopper Alloy, Au Plating
Hex Nut / Gland Nut / ClampPA66
Gasket / O-RingSilicone
GlandNBR
Machine ScrewS15C
TerminalBeryllium Copper, Sn Plating
Technical Data
CharacteristicsDescription
Visual and Dimensional InspectionMust meet or exceed the requirements specified by the most current version of the Power Specification.
Insulation ResistanceDC500V±10%‚ test for 1 minute and the insulation resistance should be more than 100MΩ
Dielectric Withstanding Voltage2500 V DC/AC peak, contact-to-contact, for 1 minute.
Contact Resistance10mΩ at 10mA Max.
Durability200 cycles insertion/extraction cycles at a maximum rate of 500cycles per hour.
Cable Pull-OutAfter the application of a steady state axial load of 45 N for one minute.
Machine Screw ForceInsert stripped wire into screw-in pin, tighten. [2.0 Nm]min.
Physical ShockNo discontinuities of 1 μs or longer duration when mated Power connectors are subjected to 11 ms duration 30 Gs half-sine shock pulses. Three shocks in each direction applied along three mutually perpendicular planes for a total of 18 shocks.
Random VibrationThe electrical load conditions shall be 100mA maximum for all contacts.
Frequency: 50 to 2000 Hz
PDS: 0.04 g? /Hz.
Duration: 1 Hour/Axis, 3 Axes Total.
g’s: 7.56 g rms
Thermal Shock5 cycles at -40° / +105°,after the test, the function and appearance can’t be impacted.
Humidity Life96 hours minimum (seven step cycles).
Salt SprayThe test liquid (Nacl) thickness is 5%, Compressing the air pressure is 0.083Mpa, Spraying amount is 1~2 ml/80cm/h, Temperature of the pressure barrel is 43°, LAB temperature is 35°, relative humidity of LAB is 95%~98%, test time is 48 hours, after the test, check if there is rusty and oxidized phenomenon.
Waterproof TestSubmersion in water 1 meter for 30 minutes.
Temperature Life85° for 48Hours Method A, Mated
Cycling Humidity4 cycles at 25° / +85° 95% RH (1 cycles/day)
UV Exposure24 H equal 1 year
8 h UV at 70 (±3) ° Black Panel Temperature
4 h Condensation at 50 (±3) ° Black Panel Temperature