C4 Dual USB 2.0 Square Flange Receptacle
kr.0
Blunt Cut
Description
Material
Panel Housing | PPS |
Panel Cap | Pa66 |
Spring | SUS |
Screw | SUS |
Rivet | Aluminum |
Rubber Pad | Silicone |
Screw Gasket | EPDM |
Sealing | Epoxy |
USB Receptacle Housing | PBT |
USB Receptacle Contacts | Copper Alloy , Au Plating |
USB Receptacle Shell | Copper Alloy,Ni Plating |
Technical Data
Characteristics | Description |
Visual and Dimensional Inspection | Must meet or exceed the requirements specified by the most current version of the USB Specification. |
Insulation Resistance | DC500V±10%,test for 1 minute and the insulation resistance should be more than1000MΩ |
Dielectric Withstanding Voltage | 500 V DC/AC peak, contact-to-contact, for 1min. 750 V DC/ AC peak, contact-to-test panel or contact-to-shield for 1 min. |
Contact Resistance | 30mΩ at 10mA Max. |
Insertion and withdrawal forces | Speed: 10 mm/s maximum. Insertion:35 N maximum at a maximum rate of 12.5 mm(0.492”) per minute. Withdrawal:10 N minimum at a maximum rate of 12.5 mm(0.492”) per minute. |
Durability | 1500 cycles ,rate of 200 cycles per hour. |
Physical Shock | No discontinuities of 1 μs or longer duration when mated USB connectors are subjected to 11 ms duration 30 Gs half-sine shock pulses. Three shocks in each direction applied along three mutually perpendicular planes for a total of 18 shocks. |
Random Vibration | The electrical load conditions shall be 100mA maximum for all contacts. Frequency: 50 to 2000 Hz PDS: 0.04 g² /Hz. Duration: 1 Hour/Axis, 3 Axes Total. g’s: 7.56 g rms |
Thermal Shock | 5 cycles at -40°C / +105°C,after the test, the function and appearance can’t be impacted. |
Salt Spray | The test liquid (Nacl) thickness is 5%, Compressing the air pressure is 0.083Mpa, Spraying amount is 1~2 ml/80cm/h,Temperature of the pressure barrel is 43℃,LAB temperature is 35℃,relative humidity of LAB is 95%~98%,test time is 48hr,after the test, check if there is rusty and oxidized phenomenon |
Waterproof Test | Water projected by a nozzle (6.3 mm) against enclosure from any direction shall have no harmful effects. Test duration: at least 15 minutes Water volume: 12.5 litres per minute Pressure: 30 kPa at distance of 3 m |
Temperature Life W/O Electrical Load | 85℃ for 96 Hours . |
Low Temperature | -40℃ for 96 Hours |
Temperature | 4 cycles at 25°C / +65°C 95%RH (1 cycles/day) |
UV Exposure | 24 H equal 1 year: 8 h UV at 70 (±3) °C Black Panel Temperature 4 h Condensation at 50 ( ±3) °C Black Panel Temperature |